Power The 400 KVA dedicated electricity supply was designed and installed to meet diverse electrical needs. Power is routed through a lightning protection system, Generator changeover panel and redundant UPS’s before getting to the servers. This ensures that all power to the servers is supplied at a smooth rate.
UPS Two 200 KVA Uninterruptible Power Supplies protect the network in case of power failure. Should the power to the network fail, high power UPS automatically kicks in to take the load of all the servers and network hardware.
Generator As a second line of defence against power failure the data centre have installed three industrial generators, capable of supplying enough electricity to the entire data centre and office area for an indefinite period of time. This means that in the event of a major utility power failure your web site will still be available.
Lightning Protection To guard against the threat of lightning (which could send spikes through the electricity supply and damage servers) a Furse lightning protection system has been installed. If an illegal spike is detected the system automatically takes this spike and destroys it. This system provides protection between all sets of conductors (phase to neutral, phase to earth and neutral to earth) ensuring total protection and closing all transient paths to equipment.
Fire Protection Fire Alarms are in place with very early smoke detection apparatus (VESDA) installed. Should a fire break out in the data centre then an FM200 Fire Suppression System will be triggered, in seconds FM200 gas will be released into the room extinguishing the fire. FM200 is a computer friendly gas that will not harm computers or leave a residue.
Air Conditioning The data centre is equipped with powerful air conditioning systems to maintain a consistently controlled environment at 16 degrees.
Water Detection In the unlikely event that water leaks into the data centre then sensors throughout the area will detect the leak and sound the alarm to on site network operations centre staff.
High Security The data centre was built with security in mind, equipped with the latest in access control and intruder protection systems fully protected and linked to the RedGuard system that will notify the Police automatically in the event of a security breach. With five levels of security from entering the building to the data centre, it is restricted by pin number access, key and motion sensors. It is also monitored by CCTV recording systems at all times.
|